DESCRIPTION
This Royal Cozy Fires Decorative Fuel Effect gas fire has been developed to give a realistic coal burning
appearance with the convenience of gas. The fire is complemented with an attractive marblesque frame. The
appliance has been constructed to enable it to be installed in most applications, where the warmth and comfort of an
open fire and a high radiant heat is required. This appliance is intended for decorative purposes, the coal bed uses
ceramic simulated (coals) to give a realistic appearance and also to allow secondary air to be entrained into the bed
that will ensure clean combustion. An aerated twin ported steel burner is used, running parallel across the front of
the fire. A single gas control with a variable high to low setting is also used combined with a Flame Supervision
Device (FSD). This is fitted to ensure that should the pilot become extinguished for any reason, (including turning
off the appliance) the gas supply to the burner is cut-off until a full lighting sequence is repeated. A separate Piezo
Igniter is used to ignite an Oxy/pilot sensor (ODS) which will cause the appliance to (shut off) in the event of
continued spillage occurring under hazardous or blocked flue conditions. The fire bed consists of ceramic fibre
components and coals all of that are removable for cleaning purposes when required. It is important when relaying
the coal bed and coals to follow the instructions correctly.
This appliance is suitable for installation into the following flues:
7" minimum diameter flues (CLASS I)
5" minimum diameter flues (CLASS 2)
Pre-Cast flues to BS 1289 Pt. I 1986.
The installation must always be used in conjunction with a suitable hearth surround- (refer to page 5 for further
details).
TECHNICAL DATA
Overall height of Marblesque frame=696mm
Overall height of appliance without frame=605mm
Overall width of frame=680mm
Overall width of appliance without frame=470mm
Minimum height of opening required=540mm
Maximum height of opening required=590mm
Minimum width of opening required=405mm
Maximum width of opening with spacer=470mm
Forward projection from opening (with fret)=165mm
Minimum depth of opening required see figs 1,2 & 3.
(See Page 18 for overall dimensions Figs. 20 & 17).
TYPE OF GAS G20 Only
Supply Pressure 20 mbar +1-1 mbar (Cold)
GAS INPUTS (Gross)
Max. 6.6 kW (22520 Btu/h)
Min. 3.8 kW (13000 Btu/h)
Pilot 0.26kw (890 Btu/h)
Main Injector TypeStereomatic 046/19/196/76M
PilotOP Oxy/Pilot NO 9022
GAS CONNECTION8mm OD Tube
WEIGHT (Two Packs) 17.5kg and 23.5kg
O
Decorative Marblesque Frame Details Temperature raC) Mted -axim Cluass Om (100
Front Fret and Canopy - cast Iron, Painted Black.
Installation Regulation and Requirements
The appliance must be installed by a competent person in accordance with the current Gas Safety (Installation and
use) Regulations, the rules in fence and in accordance with the manufacturer?s instructions, failure to do so could
lead to prosecution.
- 2 - |